44 2033180199

Assessment of Radon Gas Concentration at Ayoon Al-Hammam, Alkora-Jordan Water Purification Plant

Islam Abd-Alhadi Salem Khraisat, Barakat Al-Bataina, Sameh Gharaibeh

The 222Rn measurements were conducted using passive diffusion radon dosimeter containing CR-39 detectors from the extraction wells until it reached the consumer. The results showed that the average radon gas concentrations from all wells was (3.2 Bq/l ±0.3 Bq/l), while the average radon gas concentrations for the three pump stations was (3.1 Bq/l ±0.1 Bq/l), and the average for tap water was (2.0 l Bq/l ±0.1 Bq/l). All the obtained  results were below the maximum allowed concentration level  prescribed by US- Environmental Protection Agency (11.1Bq/l). The total annual effective dose for all water samples varies from (0.01mSV/y) to (0.08 mSv/y), which is less than the maximum contaminant level (0.1 mSv/y). Hence, the groundwater in the study area does not pose health risks to consumers because the health risk factor for having lung cancer was estimated to be (0.005 %) However, the 222Rn concentrations can be significantly improved, if the plant includes an aeration unit.

अस्वीकृति: इस सारांश का अनुवाद कृत्रिम बुद्धिमत्ता उपकरणों का उपयोग करके किया गया है और इसे अभी तक समीक्षा या सत्यापित नहीं किया गया है।
 
संघों, समाजों और विश्वविद्यालयों के लिए सहकर्मी समीक्षा प्रकाशन pulsus-health-tech